ISO 9001:2000

(495) 123-32-01

Преобразователь частоты ALTIVAR 630

Преобразователь частоты ALTIVAR 61q

Купить Преобразователи частоты ALTIVAR 630 от Schneider Electric  или узнать цену можно любым удобным для Вас способом:

по телефону +7(495) 229-36-09

по e-mail: sales@en-el.ru
на сайте
заказать


Бесплатная доставка
 

Скачать руководство по программированию ALTIVAR 630(англ. язык. 7,32Мб)

Market segments,  applications  ALTIVAR 630 

  • Water & wastewater
    • pumping
    • drilling
    • suction
    • dosing
    • odor control 
    • ventilation
    • gas compression
    • sludge removal
  • Oil & gas
    • Hydrocarbon production:
    • drilling
    • offshore and onshore extraction
    • water treatment and re-injection
    • crude oil storage
    • separation
    • pipeline pumping
    • storage
    • refining
    • DOF (digital oil field)
  • Mining, minerals & metals
    • Floatation and thickening
    • Rinsing and filtration
    • Mine shaft pumping
    • Preheater fan
    • Waste gas evacuation
    • Cooling fan
    • Separator for vertical roller mill
    • Storage and loading
    • Water supply
    • Pumping
    • Drying fan
  • Food & beverage
    • Pumping
    • Drying fans

 
Degree of protection IP 21/UL Type 1 IP 21 Floor standing
Power range for 50...60 Hz line supply (kW/HP) 0.75...160/1...250 110...315
Three-phase: 200...240  V (kW/HP) 0.75...75/1...100
Three-phase: 380...440 V (kW/HP) 110...315
Three-phase: 380...480  V (kW/HP) 0.75...160/1...250

 

Variable speed drives Altivar Process. Supply voltage three-phase 200...240 V 50/60 Hz. THDI y 44% at 100% load in Normal Duty

Motor. Power
indicated on
rating plate (2),
ND:
Motor.
Nor
mal duty (4)
Heavy
duty (5),
kW
Motor.
Normal duty (4)
Heavy duty (5),
HP
Line supply.
Line current (3)
200V,
A
Line supply.
 Line current (3)
240V, A
Line supply.
Apparent
power
240 V,
kVa
Line supply.
Max.
prospective
line Isc
kA
Altivar
Process.
Max.
continuous
current (2),
A
Altivar Process.
Max. transient
current for
60 s, A
Reference
(1) 
Altivar
Process.
Weight,
kg/lb
ND 0,75 1 3 2,6 1,1 50 4,6 5,1 ATV630U07M3 4.300/9.480
HD 0,37 0,5 1,7 1,5 0,6 50 3,3 5    
ND 1,5 2 5,9 5 2,1 50 8 8,8 ATV630U15M3 4.300/9.480
HD 0,75 1 3,3 3 1,2 50 4,6 6,9    
ND 2,2 3 8,4 7,2 3 50 11,2 12,3 ATV630U22M3 4.500/9.921
HD 1,5 2 6 5,3 2,2 50 8 12    
ND 3 - 11,5 9,9 4,1 50 13,7 15,1 ATV630U30M3 4.500/9.921
HD 2,2 3 8,7 7,6 3,2 50 11,2 16,8    
ND 4 5 15,1 12,9 5,4 50 18,7 20,6 ATV630U40M3 4.600/10.141
HD 3 - 11,7 10,2 4,2 50 13,7 20,6    
ND 5,5 7,5 20,2 17,1 7,1 50 25,4 27,9 ATV630U55M3 7.700/16.976
HD 4 5 15,1 13 5,4 50 18,7 28,1    
ND 7,5 10 27,1 22,8 9,5 50 32,7 36 ATV630U75M3 7.700/16.976
HD 5,5 20 20,2 17,1 7,1 50 25,4 38,1    
ND  11 15 39,3 32,9 13,7 50 46,8 51,5 ATV630D11M3  13.800/30.424 
HD  7,5 10 27,2 23,1 9,6 50 32,7 49,1    
ND  15 20 52,6 45,5 18,9 50 63,4 69,7 ATV630D15M3 27.300/ 60.186
HD  11 15 40,1 34,3 14,3 50 46,8 70,2    
ND  18,5 25 66,7 54,5 22,7 50 78,4 86,2 ATV630D18M3  27.300/ 60.186
HD  15 20 53,1 44,9 18,7 50 63,4 95,1    
ND  22 30 76 64,3 26,7 50 92,6 101,9 ATV630D22M3  27.300/ 60.186
HD  18,5 25 64,8 54,5 22,7 50 78,4 117,6    
ND  30 40 104,7 88,6 36,8 50 123 135,3 ATV630D30M3  56.600/ 124.781
HD  22 30 78,3 67,1 27,9 50 92,6 138,9    
ND  37 50 128 107,8 44,8 50 149 163,9 ATV630D37M3  56.600/124.781 
HD  30 40 104,7 88,6 36,8 50 123 184,5    
ND  45 60 155,1 130,4 54,2 50 176 193,6 ATV630D45M3  56.600/ 124.781
HD  37 50 128,5 108,5 45,1 50 149 223,5    
ND 55 75 189 161 61,1 50 211 232,1 ATV630D55M3(6) 84.00/185.2
HD 45 60 156 134 50 50 176 264    
ND 75 100 256 215 83,7 50 282 310,2 ATV630D75M3(6) 84.00/185.2
HD 55 75 189 161 61,1 50 211 316,5    

(1) Altivar Process ATV630U07M3...D75M3 drives have been designed without an EMC filter. An additional filter can be added to help meet more stringent requirements and reduce electromagnetic emissions.

(2) These values are given for a nominal switching frequency of 4 kHz up to ATV630D22M3, or 2.5 kHz for ATV630D30M3...D75M3 for use in continuous operation. The switching frequency is adjustable from 2...12 kHz for all ratings. Above 2.5 or 4 kHz (depending on the rating), the drive will automatically reduce the switching frequency in the event of an excessive temperature rise. For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves on our website www.schneider-electric.com).

(3) Typical value for the indicated motor power and for the maximum prospective line Isc.

(4) Values given for applications requiring a slight overload (up to 110%).

(5) Values given for applications requiring a significant overload (up to 150%).

(6) IP21 / UL Type 1 with additionnal option VW3A9704.Note: Consult the summary tables of possible drive, option, and accessory combinations (see page 60824/2).

 

 Variable speed drives Altivar Process. Supply voltage three-phase 380...480 V 50/60 Hz. IP 21/UL type 1, 380...480 V drives with integrated category C2 or C3 EMC filter (6). THDI y 44% at 100% load in Normal Duty

 
Motor.
Power indicated
on rating plate,
ND:
Motor.
Normal duty (3)
Heavy duty (4),
kW
Motor.
Normal duty (4)
Heavy duty (5),
HP
 Line supply.
Line current (2)
380V, A
Line supply.
Line current (2)
480V, A
Line supply.
Apparent
power
380 V,
kVa
Line supply.
Max.
prospec-
tive
 line Isc
kA
Altivar Process.
Max.
continuous
current,
A
Altivar Process.
Max. transient
current for 60 s,
A
Altivar Process.
Reference
(1) 
Altivar Process.
Weight,
kg/lb
ND 0,75 1 1,5 1,3 1,1 50 2,2 2,4 ATV630U07N4 4.500/9.480
ND 0,37 0,5 0,9 0,8 0,7 50 1,5 2,3    
ND 1,5 2 3 2,6 2,2 50 4 4,4 ATV630U15N4 4.500/9.921
ND 0,75 1 1,7 1,5 1,2 50 2,2 3,3    
ND 2,2 3 4,3 3,8 3,2 50 5,6 6,2 ATV630U22N4 4.500/9.921
ND 1,5 2 3,1 2,9 2,4 50 4 6    
ND 3 - 5,8 5,1 4,2 50 7,2 7,9 ATV630U30N4 4.600/10.141
ND 2,2 3 4,5 4 3,3 50 5,6 8,4    
ND 4 5 7,6 6,7 5,6 50 9,3 10,2 ATV630U40N4 4.600/10.141
ND 3 - 6 5,4 4,5 50 7,2 10,8    
ND 5,5 7,5 10,4 9,1 7,6 50 12,7 14 ATV630U55N4 4.700/10.362
ND 4 5 8 7,2 6 50 9,3 14    
ND 7,5 10 13,8 11,9 9,9 50 16,5 18,2 ATV630U75N4 7.700/16.976
ND 5,5 7,5 10,5 9,2 7,6 50 12,7 19,1    
ND 11 15 19,8 17 14,1 50 23,5 25,9 ATV630D11N4 7.700/16.976
ND 7,5 10 14,1 12,5 10,4 50 16,5 24,8    
ND 15 20 27 23,3 19,4 50 31,7 34,9 ATV630D15N4 13.600/ 29.983
ND 11 15 20,6 18,1 15 50 23,5 35,3    
ND 18,5 25 33,4 28,9 24 50 39,2 43,1 ATV630D18N4 14.200/31.306
ND 15 20 27,7 24,4 20,3 50 31,7 47,6    
ND 22 30 39,6 34,4 28,6 50 46,3 50,9 ATV630D22N4 14.300/ 31.526
ND 18,5 25 34,1 29,9 24,9 50 39,2 58,8    
ND 30 40 53,3 45,9 38,2 50 61,5 67,7 ATV630D30N4 28.000/ 61.729
ND 22 30 40,5 35,8 29,8 50 46,3 69,5    
ND 37 50 66,2 57,3 47,6 50 74,5 82 ATV630D37N4 28.200/ 62.170
ND 30 40 54,8 48,3 40,2 50 61,5 92,3    
ND 45 60 79,8 69,1 57,4 50 88 96,8 ATV630D45N4 28.700/ 63.273
ND 37 50 67,1 59 49,1 50 74,5 111,8    
ND 55 75 97,2 84,2 70 50 106 116,6 ATV630D55N4 56.500/ 124.561
ND 45 60 81,4 71,8 59,7 50 88 132    
ND 75 100 131,3 112,7 93,7 50 145 159,5 ATV630D75N4 58.000/ 127.868
ND 55 75 98,9 86,9 72,2 50 106 159    
ND 90 125 156,2 135,8 112,9 50 173 190,3 ATV630D90N4 58.500/ 128.970
ND 75 100 134,3 118,1 98,2 50 145 217,5    
ND 110 150 201 135 121,8 50 211 232,1 ATV630C11N4 (5) 85.000/187.39
ND 90 125 170 143 102,6 50 137 259,5    
ND 132 200 237 213 161,4 50 250 275 ATV630C13N4 (5) 85.000/187.39
ND 110 150 201 165 121,8 50 180 270    
ND 160 250 284 262 201,3 50 302 332,2 ATV630C16N4 (5) 85.000/187.39
ND 132 200 237 213 161,4 50 240 360    

 

Variable speed drives. Altivar Process. Supply voltage three-phase 380...440 V 50/60 Hz. IP 21, 380...440 V drives in floor standing with integrated category C3 EMC filter. THDI y 44% at 100% load in Normal Duty

Motor.
Power indicated
on rating plate,
ND:
Motor.
Normal duty (3)
Heavy duty
(4), kW
Motor.
Normal duty (4)
Heavy duty (5),
HP
Line supply.
Line current (2)
380V, A
Line supply.
Line current (2)
400V, A
Line supply.
Apparent
power
380 V,
kVa
Line supply.
Max.
prospective
line Isc
kA
Altivar Process.
Max.
continuous
current, A
Altivar Process.
Max. transient
current
for 60 s, A
Altivar Process.
Reference (1) 
Altivar Process.
Weight, kg/lb
ND 110 N/A 207 195 135 50 211 232 ATV630C11N4F 300.000/661.387
ND 90 N/A 174 164 113 50 173 259    
ND 132 N/A 250 232 161 50 250 275 ATV630C13N4F 300.000/661.387
ND 110 N/A 207 197 136 50 211 316    
ND 160 N/A 291 277 192 50 302 332 ATV630C16N4F 300.000/661.387
ND 132 N/A 244 232 161 50 250 375    
ND 200 N/A 369 349 242 50 370 407 ATV630C20N4F 400.000/881.850
ND 160 N/A 302 286 198 50 302 453    
ND 250 N/A 453 432 299 50 477 524 ATV630C25N4F 400.000/881.850
ND 200 N/A 369 353 244 50 370 555    
ND 315 N/A 566 538 373 50 590 649 ATV630C31N4F 400.000/881.850
ND 250 N/A 453 432 299 50 477 715    

(1) These values are given for a nominal switching frequency of 4 kHz, settable from 2 to 12 kHz up to ATV630D45N4, or 2.5 kHz, settable from 2 to 8 kHz for ATV630D55N4...C16N4 and ATV630C11N4F...C16N4F  for use in continuous operation.
Above 2.5 or 4 kHz (depending on the rating), the drive will automatically reduce the switching frequency in the event of an excessive temperature rise. For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves on our website www.schneider-electric.com).
(2) Typical value for the indicated motor power and for the maximum prospective line Isc.
(3) Values given for applications requiring a slight overload (up to 110%).
(4) Values given for applications requiring a significant overload (up to 150%).
(5) IP21 / UL Type 1 with additionnal option VW3A9704.
(6) C2 EMC filter for ATV630U07N4 to ATV630D45N4, C3 EMC filter above ATV630D45N4.

 

Presentation of the offer 

Altivar Process drives can help improve equipment performance and reduce exploitation costs by optimizing energy consumption and user comfort.

They provide integrated safety and automation functions that meet the requirements of the most demanding applications.
They also have various optional communication cards available for seamless  integration into the main automation architectures.
Altivar Process drives feature numerous configurable I/O as standard to facilitate adaptation to specific applications.
They offer a plug & play solution, whereby parameters are preset in the factory to the desired configuration, to help save process control and operating time.
Altivar Process is available on wall-mounting IP21/IP55 and on floor standing IP21/IP54.
Altivar Process drives can also be supplied as a customized solution developed by Schneider Electric based on customer specifications.

Rugged

Altivar Process drives are designed to adapt to significant levels of thermal stress and to the harshest environments.

  • Operating temperature (for continuous monitoring)
    •   Mounted in enclosure:
      • mounted singly or side-by-side: -15...+50 °C/+5 ...122 °F, 50...60°C/122...140 °F with derating
      • option to mount the power section separately (patent No. RUE-2192 "flange-mounting kit")
  •  Wall-mounted and Floor standing: 
      • plant room: 50 °C/122 °F (max.)
      • harsh environment: 40 °C/104 °F (max.)
  • Storage and transport temperature: -40...+70 °C/-40...+158 °F
  • Operating altitude:
    •  0...1,000 m/0...3,281 ft without derating
    •  1,000...4,800 m/3,281...15,748 ft with derating of 1% per 100 m/328 ft
  • Withstand to harsh environments:
    •  chemical class 3C3 conforming to IEC/EN 60721
    •  mechanical class 3S3 conforming to IEC/EN 60721
    •  electronic cards with protective coating  
  • Protection to suit requirements:
    • IP 21/UL type 1 for wall-mounting and mounting in enclosure 
    •  IP 55/UL type 12 for custom mounting, with protection against dust and water jetsEnergy

Altivar Process drives help to optimize power consumption by reducing the rms nput current for the same load.

  •  Standard offer:
    •   THDI y 44% at 100% load
    •   THDI y 48% for 80 to 100% load, which corresponds to typical use to maintain  the power factor
  •   Low harmonic offer compatible with standard IEEE 519
  •   Low power:

Depending on the model, Altivar Process drives can also reduce power consumption by up to 60% on each stop by disabling the power section, the fans, the backlight on the graphic display terminal, etc. This "stop and go" function is automatic on each stop and requires no extra investment (no line contactor or 24 V power supply required).

 Environment

Altivar Process drives have been designed to meet the requirements of environmental protection directives and regulations:

  • RoHS 2 (1)
  • REACH (2) + Substitute It Now solution (halogen-free wiring and plastics)
  • PEP (Product Environmental Profile) eco-passport program for reducing the carbon footprint and conserving raw materials
  • EoLI (End of Life Instruction) (3)
    • more than 70% recyclable materials (new ruling)
  • Efficient energy management: 30% reduction in consumption

Electromagnetic compatibility (EMC)

Compliance with electromagnetic compatibility requirements has been incorporated into the design of the drive, which simplifies installation and provides an economical means of helping to ensure equipment meets e marking requirements.
Altivar Process drives have a category C2 or C3 EMC filter, except ATV630U07M3...D75M3 models which can take an additional filter to meet more stringent requirements (see page 60827/6).

Installation/Maintenance

Altivar Process drives are ergonomically designed to adapt to any type of installation:

  • Products, systems or integrated in iMCC
  • IP 21, UL type 1; IP 55, UL type 12 ; IP 54
  • Easy installation of products and systems:
    •  cable entry equipped with Romex cable glands to maintain an EMC connection for the power and control cable
    • color code for connections to the display terminal and control terminals
    • long cable: up to 150 m with category C3 EMC filter
  • Asynchronous or synchronous drive in open loop for 0.1...500 Hz output frequency
  • Special motors: submersible and tapered rotor motors
  • Lower maintenance costs due to drive’s ergonomic design:
    • fans can be replaced in less than 5 minutes
    • no maintenance tool required
    • limited number of parts
  • Embedded web server:
    • compatible process elements for easier implementation
    • direct worldwide access to monitoring and maintenance functions:
        - reading values
        - modifying data
        - configuring parameters
        - changing controller status

(1)   European directive 2002/95/EC Restriction Of Hazardous Substances (applicable in 2016)

(2) European regulation No. 1907/2006

(3) According to IEC 62635 Guidelines

Скачайте опросный лист на подбор и поставку преобразователей частоты ALTIVAR 630 от  Schneider Electric (Шнайдер Электрик), заполните и отправьте на email sales@en-el.ru  - наши специалисты помогут Вам подобрать оборудование, наиболее полно отвечающего требованиям Вашего предприятия.

09 августа 2017
Переезд офиса "Эн-Эл"
Мы переехали в новый офис. Обратите внимание - новый телефон компании +7 (495) 123-32-01
02 июня 2015
Испытания лифтовых преобразователей частоты Inovance МD320L и Inovance МD380L.
В испытательном центре ОАО “Щербинский лифтостроительный завод” в составе лифта ПП-1016Щ (грузоподъемность 1000 кг) вместе с приводом ЕПМ прошли испытания преобразователей частоты серии Inovance МD320L и Inovance МD380L.
14 апреля 2015
Мини-выставка и презентации лифтов: традиции и инновации
В рамках съезда Лифтовиков прошла ставшая уже традиционной мини-выставка лифтов и лифтового оборудования.
10 марта 2015
Тормозные резисторы от Danfoss
В ассортименте продукции, поставляемой Эн-Эл появились тормозные резисторы для преобразователей частоты Danfoss.
26 ноября 2014
Национальный горнопромышленный форум в Москве
27 ноября 2014 года в Москве, в Центре Международной торговли состоится Первый национальный горнопромышленный форум.
Все новости
Адрес: 123380, г. Москва, пр-т Маршала Жукова 1, стр. 1 +7 (495) 123-32-01
E-mail: mail@en-el.ru